Use the following chart to analyze what is happening with your BTR.
| LED |
Signal Monitored |
Description |
| D1 |
READY(H) |
When the board is powered on
this LED briefly goes on then off indicating that the BTR is ready to
operate. This is the same signal that is on pin 14 of J2, the connector that
goes to the DNC computer. When pin 14 is +12v, D1 goes off. |
| D2 |
FROM_DNC |
Normally on. Flashes when there
is RS-232 data flow from the DNC computer. Pin 15 of J2. |
| D3 |
TO_DNC |
Normally on. Flashes when there
is RS-232 data flow to the DNC computer from the BTR. Pin 17 of J2. |
| D4 |
RUN(L) |
This is the AND’ed combination
of DATA REQUESTand SPROCKET. On BTR Rev 0 this signal is normally on when no
data request is coming from the controller. On BTR Rev 1and 2 it is normally
off. It flashes on/off when data is requested indicating part program data
flow from BTR to controller. The signal for this LED is brought to pin 10 of
J2. |
| D5 |
REV(L) |
Goes off when controller
requests data in the reverse direction. J4 pin 43. |
| D6 |
RS-232_IN |
Normally on. Flashes when there
is RS-232 data flow from an outside source (CNC serial punch port, for
example.) Pin 2 of J2. |
| D7 |
RS-232_OUT |
Normally on. Flashes when there
is RS-232 data flow to an outside source. Output occurs on this line
whenever parallel PTR data is being output. Pin 2 of J2. |
| D8 |
SELPTR(L) |
On when DNC/PTR switch is in the
DNC position. |
| D9 |
RST(L) |
Normally on. Goes off briefly
when the reset signal is forced during the power on cycle and between queued
files. J4 pin 45. |
| D10 |
FROM_CNC(L) |
Normally on. Goes off when a job
is queued to be receive via the FACIT port (J5.) |
| D11 |
TO_CNC(L) |
Normally off. This is the power
on default state. Indicates that a job can be queued to be sent to the
NC/CNC via the parallel personality card port, J4. |
| D12 |
SERIAL_IN(L) |
Normally on. Goes off when a job
is queued to be received via the serial input. Pin 2 of J2. |
| D13 |
EN_PNCH(L) |
Normally on. Goes off when the
FROM_CNC(L) signal is TRUE and the DNC/PTR switch is in the DNC position. |
| D14 |
EN_DNC(L) |
Normally off. The power on
default state if the DNC/PTR switch is in the DNC position. This is the
TO_DNC(L) signal AND’ed with the DNC/PTR switch. |
| D15 D16
D17
D18
D19
D20
D21
D22 |
DATA0 DATA1
DATA2
DATA3
DATA4
DATA5
DATA6
DATA7 |
Shows the states of the 8 data
bits on the parallel personality card port, J4 pins 23-37. LED is on if bit
is in the logic 1 state (+5 volts) and off if logic 0 (0 volts.) |
| D23 |
STROBE |
The SPROCKET(H) signal on the
parallel personality card port, J4 pin 39. Normally on. Goes off between
data characters. |
| D24 |
DATA REQUEST |
Shows the state of the DIRUN(H)
signal on the parallel personality card port, J4 pin 41. Goes on when
DIRUN(H), the CNC is data request signal is logic 1. |
If you have any questions and you have a Hardware Service Contract with CCI
you can call/E-mail/Fax us anytime and we will
provide the needed Engineering support you require and hardware replacement to
get you up and running as soon as possible.